Quantum 1200 Series DAT Autochanger Guida Utente Pagina 264

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 294
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 263
REQUEST SENSE Command (03h) SDLT 600 SCSI Interface Guide
4-222 January 2005 81-81200-02 REV A01
NOT READY 02h 04h 00h Unit Not Ready, Cause Nonreportable
04h 01h Unit Not Ready, Calibration in Process
04h 02h Unit Not Ready, LOAD Command Needed. A
tape cartridge is loaded but the tape medium is in
an unloaded state.
04h 03h Unit Not Ready, Manual Intervention Needed. No
tape cartridge is present or a mechanical failure
has occurred.
04h 07h Unit Not Ready, Loader Operation in Progress
25h 90h Bad Code Update Image Header
30h 00h Incompatible Medium Installed
30h 02h Incompatible Format
30h 03h Cleaning Cartridge Installed
3Ah 00h Medium Not Present
3Eh 00h Logical Unit Has Not Self-Configured Yet
52h 00h Cartridge Error, Calibration Failure
53h 00h Media Load or Eject Failed
5Ah 01h Operator Media Removal Request
MEDIUM
ERROR
03h 00h 00h Medium Error
00h 17h Cleaning Required
0Ch 00h WRITE Error
11h 00h Unrecovered READ Error
11h 03h Incomplete Block READ
11h 08h Incomplete Block READ (Partial Record Found)
14h 00h Recorded Entity Not Found. Logical DLT block
not found
15h 02h Position Error Detected by Read of Medium
3Bh 00h Sequential Positioning Error
3Bh 08h Repositioning Error
Table 4-131. Supported ASC / ASCQ (Hex) for REQUEST SENSE Command (Continued)
Text Name Sense Key ASC ASCQ Description
Vedere la pagina 263