Chapter 2 Media Changer Commands
Log Sense Command (4Dh)
Quantum SuperLoader 3 Software Interface Guide 39
Table 17 Parameters for
Device Status Log Sense Page
Figure 24 Device Status Log
Sense Page (0001h)
Field Name Description
Parameter Code Parameter Codes 0000h through 0004h are supported:
Code Description
0000h Specifies device type. This value is always 0h.
0001h Specifies device status (figure 24
).
0002h Specifies the number of move operations over the lifetime of the device.
0003h Reserved for media changer device and shall contain 0.
0004h Vendor specific
DU
Disable Update. Always 0.
DS
Save not supported, always 1.
TSD
Target Save Disable not supported, always 1.
ETC
Enable Threshold Comparison. Threshold checking is not supported on
this page. Always set to 0.
TMC
Threshold Met Criteria. Always 0.
LP
List Parameter. Always set to 0 (parameter codes treated as data
counter).
Bit
Byte76543210
0
Reserved
1
Reserved Temperature Status
2 - 3
Reserved
Vedere la pagina 54