AML/2 Hardware Components 2-7
07 Nov 2003
Figure 2-5 Single AML/2 Quadro Tower (Top View)
The average time to retrieve and mount a cassette is between
2.5 and 6 seconds. The Quadro Tower’s performance is
optimized through weight reduction of moving components
and the use of composite materials. Computer-directed servo
mechanisms control the movement of the main tower and its
auxiliary towers. Figure 2-5 shows a top view of the Quadro