Installing and Removing Hardware 4-27
Scalar 100
Figure 4-2 Installing a Bulk Load Mailbox
To install a bulk load Mailbox
1. Attach the bulk load Mailbox to the door using eight 11/32 nuts.
2. Attach the cable clamps using 2 Phillips screws and one 11/32 nuts. Connect cable to the
display assembly.
3. Insert magazines and any tape cartridges in the Mailbox.
Cable Clamps
Mailbox cable harness
Connector to
11/32 Nuts
Multiple-Slot
(Left Side)
Mailbox Assembly
Display Assembly
Magazine