Quantum AML/E Guida Utente Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 77
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 19
For Your Safety
page 3 - 6 Operator Guide 599 DOC C00 003
3.6.2 <EMERGENCY STOP> Buttons
Information
The yellow luminous push-button <CONTROL OFF> on the operating panel
has the same function as the <EMERGENCY STOP> button.
All <EMERGENCY STOP> buttons (I/O unit …) have the same function: EMER-
GENCY STOP switches off the output electronics. All movements of the handling
unit and the storage towers stop immediately.
When persons or property are at risk immediately press the nearest <EMER-
GENCY STOP> button.
Moving parts stop at once.
WARNING!
Hazardous Voltage!
Pressing an <EMERGENCY STOP> button will not render the entire
AML/E system voltageless. Only the drive amplifiers are switched off.
Emergency stop does not switch off:
the control units of the handling unit and the storage towers
the AMU processor
the drives
the compressed air supply
Cut the power supply to these components at a suitable point (e. g. connecting plug
or switch)!
Vedere la pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 76 77

Commenti su questo manuale

Nessun commento