Installation
19
Connecting to a 68-pin Wide SCSI or LVD bus
To connect the drive to an LVD or SCSI wide bus, first turn off all power to the drive
and computer. Then attach the interface cable to the SCSI interface connector on the
back of the drive (see Figure 7).
Power connector
pin 4
+5V
pin 3: GND
(+5V return)
pin 2: GND
(+12V return)
pin 1
+12V
Ultra2 SCSI 68-pin
high-density connector
pin 34
pin 68
pin 35
pin 1
Figure 7. Interface connector on internal Scorpion 240
SCSI Termination
The internal Scorpion 240 does
not
provide SCSI termination. For this reason, it
should not be the last device on a SCSI chain. Two termination examples are shown
in Figure 8 below. If the drive is the only SCSI device, attach the drive to the
connector which is next to last on the SCSI chain and attach a multi-mode terminator
to the last connector in the chain.
SCSI Controller
(termination enabled)
Internal
Tape drive
SCSI device
(
termination
enabled
)
SCSI device
(
termination
disabled
)
SCSI device
(
termination
disabled
)
(no
termination
)
SCSI Terminator
SCSI Controller
(termination enabled)
Internal
Tape drive
(no
termination
)
Figure 8. Two SCSI termination examples for internal Scorpion 240.
Connecting a power cable
Attach a four-pin power cable to the power connector on the back of the drive (see
Figure 7 above). The recommended power connector for the internal Scorpion 240 is
an AMP 1-48024-0 housing with AMP 60617-1 pins or equivalent.