16 Scalar i500 Getting Started Guide
Connecting Fibre Channel Cables Through an I/O Blade
For each tape drive:
1 Connect one end of a Fibre Channel cable to the Fibre Channel port on the tape drive.
2 Connect the other end of the cable to an initiator port (lower ports 3 – 6) on the nearest Fibre Channel
I/O blade.
For each Fibre Channel I/O blade:
3 Connect one end of a Fibre Channel cable to one of the target ports (upper ports 1 and 2) on the Fibre
Channel I/O blade.
4 Connect the other end of the cable to your host or switch.