Pathlight VX User’s Guide 159
SNC Back Panel—FC Blade LEDs
The front panel of each FC blade provides three status LEDs and six FC activity LEDs. Figure 20 shows
their location and Table 14
describes their function.
Figure 20 FC Blade LEDs
Table 14 FC Blade LED Activity
LED Color State Description
FC1, FC3, FC5 Green Flickering I/O is occurring on the FC connection to the left of
the LED.
FC1, FC3, FC5 Green ON A connection exists, but there is no I/O.
FC2, FC4, FC6 Green Flickering I/O is occurring on the FC connection to the right of
the LED.
FC2, FC4, FC6 Green ON A connection exists, but there is no I/O.
PWR Blue Flashing 1x / 10 sec Indicates that power is on.
STS Amber OFF Indicates no health or environmental problems.
See Note beneath table.
RDY Green Flashing 1x / sec Indicates normal processor activity.
Note
Normal behavior for the FC blade PWR, STS, and RDY LEDs is not the same as normal
behavior for the utility module PWR, STS, and RDY LEDs.
During initialization, the FC blade’s amber STS LED remains ON until the firmware
enters its main scheduling loop.
If initialization fails, the FC blade’s amber STS LED remains lit and the blue PWR LED
blinks, a numeric fault code displays. Table 15
lists the numeric fault codes. If
initialization succeeds, the amber STS LED goes OFF, the green RDY LED blinks
once per second, and the blue PWR LED blinks once every 10 seconds.