Chapter 8: Installing, Removing, and Replacing Components
Removing and Replacing a Magazine
Quantum Scalar i40 and Scalar i80 User’s Guide 217
Note: If the library is turned off, you can release the magazine
manually by inserting an opened paperclip, small screwdriver,
or other object (3.5 mm or less in diameter that will not break
off) into the access hole in the bottom of the magazine bezel
(see
Figure 53). Use the tool to depress the release latch while
gently pulling outward on the magazine bezel handle.
Right-side magazines will only slide out
as far as the I/E station.
To release right-side magazines fully:
- On the Scalar i40 and the bottom right magazine of the
Scal
ar i80, reach under the open magazine and insert the tool
directly into the access hole in the library chassis to depress the
release latch, while pulling out on the magazine bezel handle.
- On the top right magazine of the Scalar i80, reach un
der the
open magazine and press the release latch directly with your
finger, while pulling out on the magazine bezel handle.
Figure 53 Magazine Release
Latch Access Holes
Magazine release latch access holes
Installing the Magazine The replacement magazine can be used on either the left or right side of
the library, depending on how it is oriented. Once it is oriented correctly,
the left or right bezel can be attached.
You can perform this procedure with the library powered on.
1 Place the removed
magazine in the orientation it would be if it were
installed in the library.