Chapter 9: Troubleshooting
Troubleshooting Library “Not Ready” Messages
Quantum Scalar i40 and Scalar i80 User’s Guide 249
The library “not ready” messages include the following, with possible
solutions listed:
Message Resolution
Library is not ready The library is initializing and becoming
ready
. Wait for the library to finish
initialization.
Library is becoming ready Wait for the library to finish
in
itialization.
Library is not initialized Most likely a problem with the robot.
Tr
y the following:
Check the diagnostic ticket and
follow the resolution steps listed (see
About Diagnostic Tickets on
page 244).
Power cycle the library to clear the
error
. If that fails, contact Quantum
Support.
Library needs manual
attention
Most likely a problem with the robot or
othe
r component. Try the following:
Check the diagnostic ticket and
follow the resolution steps listed (see
About Diagnostic Tickets on
page 244).
Power cycle the library to clear the
error
. If that fails, contact Quantum
Support.
Note: You may not see the “not ready” message in the Web client
until the browser refreshes. Similarly, even if the problem has
been resolved, the “not ready” message will not disappear
from the Web client until the browser refreshes.